| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CONTACT STIMULUS RATING | 2.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 5.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND VIBRATION PROOF AND WATERTIGHT |
| OPERATING TEMP RATING | 60.0 FAHRENHEIT MINIMUM AND 340.0 FAHRENHEIT MAXIMUM |
| OVERALL DIAMETER | 1.015 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | INPUT PORT |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PRESSURE SWITCH TYPE | GAGE |
| PROOF PRESSURE | 100.00 POUNDS PER SQUARE INCH GAGE |
| SENSING ELEMENT BURST PRESSURE | 250.00 POUNDS PER SQUARE INCH GAGE |
| WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
| STYLE DESIGNATOR | CYLINDRICAL |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |