| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 3.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 1.80 ACTUATION POINT MAXIMUM GALLONS PER MINUTE AND 1.50 DEACTUATION POINT MINIMUM GALLONS PER MINUTE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 50.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| OPERATING TEMP RATING | 0.0 CELSIUS MINIMUM AND 50.0 CELSIUS MAXIMUM |
| OVERALL HEIGHT | 3.330 INCHES MAXIMUM |
| OVERALL LENGTH | 3.250 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING METHOD | INLET CONNECTION AND OUTLET CONNECTION AND LINE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |