| BODY HEIGHT | 7.969 INCHES NOMINAL |
| BULB DIAMETER | 0.375 INCHES NOMINAL |
| BULB LENGTH | 3.750 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| CONTACT ADJUSTMENT RANGE | +100.00 TO 1000.00 ACTUATION POINT DEGREES FAHRENHEIT AND +95.00 TO 995.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT LOAD CURRENT RATING | 50.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
| FEATURES PROVIDED | CALIBRATED SCALE |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 4.531 INCHES NOMINAL |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 8.594 INCHES NOMINAL |
| OVERALL HEIGHT | 8.719 INCHES NOMINAL |
| OVERALL LENGTH | 8.594 INCHES NOMINAL |
| OVERALL WIDTH | 5.063 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
| MOUNTING METHOD | BRACKET(S) |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.781 INCHES NOMINAL |
| STYLE DESIGNATOR | RECTANGULAR |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | SCREW |