| ELECTRICAL CONNECTION TYPE | CABLE |
| ACTUATION METHOD | BUOYANCY |
| AIRCRAFT FUEL FOR WHICH DESIGNED | ALL |
| CONTACT ARRANGEMENT | SPST,NORMALLY OPEN |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES NOMINAL LOAD |
| FLOAT AND CONTACT POSITIONS | FLOAT UP, CONTACTS OPEN |
| FLOAT EFFECTIVE TRAVEL | 0.870 INCHES MINIMUM AND 1.370 INCHES MAXIMUM |
| FLOAT QUANTITY | 1 |
| LIQUID TYPE FOR WHICH DESIGNED | AIRCRAFT FUEL |
| OVERALL LENGTH | 3.940 INCHES MINIMUM AND 4.060 INCHES MAXIMUM |
| MOUNTING DIMENSIONS | MTD BY 9/16-18 NF THD CONNECTION |
| MOUNTING METHOD | THREAD |
| MOUNTING POSITION | VERTICAL |
| OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 160.0 FAHRENHEIT MAXIMUM |
| OVERALL DIAMETER | 1.380 INCHES NOMINAL |
| POWER CABLE LENGTH | 155.000 INCHES MINIMUM AND 160.000 INCHES MAXIMUM |
| RELAY | NOT INCLUDED |
| TANK INSERTION LENGTH | 2880.000 INCHES MAXIMUM |