| ELECTRICAL CONNECTION TYPE | CABLE |
| AC VOLTAGE RATING | 115.000 VOLTS NOMINAL FIRST ALTERNATE OPERATING POWER RQMT |
| AC VOLTAGE RATING | 230.000 VOLTS NOMINAL SECOND ALTERNATE OPERATING POWER RQMT |
| ACTUATION METHOD | BUOYANCY |
| CONTACT ARRANGEMENT | SPST,NORMALLY OPEN |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES RESISTIVE LOAD AND 5.0 AMPERES RESISTIVE LOAD |
| FLOAT EFFECTIVE TRAVEL | 0.250 INCHES NOMINAL |
| FLOAT QUANTITY | 2 |
| FREQUENCY RATING | 60.000 HERTZ NOMINAL SECOND ALTERNATE OPERATING POWER RQMT |
| FREQUENCY RATING | 60.000 HERTZ NOMINAL FIRST ALTERNATE OPERATING POWER RQMT |
| FSC APPLICATION DATA | SWITCH,FLOAT,LIQUID LEVEL,EXCEPT ENGINE |
| LIQUID TYPE FOR WHICH DESIGNED | LUBRICATING OIL |
| OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 125.0 FAHRENHEIT MAXIMUM |
| OVERALL DIAMETER | 2.000 INCHES NOMINAL |
| OVERALL LENGTH | 24.000 INCHES NOMINAL |
| MOUNTING DIMENSIONS | MTD BY 2 IN. NPT THD CONNECTION |
| MOUNTING METHOD | THREAD |
| MOUNTING POSITION | VERTICAL AND AT ANGLE TO MOUNTING CENTER |
| PHASE | SINGLE FIRST ALTERNATE OPERATING POWER RQMT |
| PHASE | SINGLE SECOND ALTERNATE OPERATING POWER RQMT |
| POWER CABLE LENGTH | 60.000 INCHES NOMINAL |
| RELAY | NOT INCLUDED |
| SPECIAL FEATURES | FLOAT IS REVERSIBLE ON STEM TO SELECT NORMALLY OPEN OR NORMALLY CLOSED POSITION |
| TANK INSERTION LENGTH | 23.000 INCHES NOMINAL |