5905-00-893-6872 RESISTOR,FIXED,WIRE WOUND Index 5940-00-893-6875 SPLICE,CONDUCTOR

National Stock Number:
5930-00-893-6873

Federal Supply Class:
5930

National Item Identification Number:
008936873

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
222-10NH1-222100019278DETROIT SWITCH INC
MIL-DTL-221281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC217481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC221281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH4.782 INCHES NOMINAL
BULB DIAMETER0.688 INCHES NOMINAL
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT ADJUSTMENT RANGE+110.00 TO 185.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT LOAD CURRENT RATING13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 DC AT SEA LEVEL FOURTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 DC AT SEA LEVEL THIRD VOLTAGE
FREQUENCY IN HERTZ60.0 SINGLE VOLTAGE
OVERALL HEIGHT8.031 INCHES NOMINAL
OVERALL LENGTH5.000 INCHES NOMINAL
OVERALL WIDTH2.688 INCHES NOMINAL
MOUNTING METHODINLET CONNECTION
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
TEMP SENSING ELEMENT TYPEBULB
TERMINAL TYPETAB W/SCREW