| BODY DIAMETER | 0.500 INCHES NOMINAL |
| BODY LENGTH | 2.000 INCHES MAXIMUM |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | +0.00 TO 300.00 ACTUATION POINT DEGREES FAHRENHEIT AND -2.00 TO 298.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT TONGUE AND EXTERNAL DEACTUATION POINT TONGUE |
| CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD AND 125.0 MILLIAMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD AND 25.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 185.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 183.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL THIRD VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
| FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | IMMERSION WELL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 300.0 FAHRENHEIT MAXIMUM |
| OVERALL DIAMETER | 0.500 INCHES NOMINAL |
| OVERALL LENGTH | 2.188 INCHES MAXIMUM |
| STYLE DESIGNATOR | CYLINDRICAL |
| TEMP SENSING ELEMENT TYPE | IMMERSION WELL |
| TERMINAL TYPE | TAB, SOLDER LUG |