| BULB DIAMETER | 0.375 INCHES NOMINAL |
| BULB LENGTH | 3.125 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 60.000 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +100.00 TO 240.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
| CONTACT LOAD CURRENT RATING | 25.0 MILLIAMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 8.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 12.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
| FEATURES PROVIDED | CALIBRATED SCALE |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | BASE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| OVERALL HEIGHT | 5.625 INCHES NOMINAL |
| OVERALL WIDTH | 2.000 INCHES NOMINAL |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | TAB W/SCREW |