| BODY LENGTH | 1.156 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CONTACT STIMULUS RATING | 10.50 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 7.50 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 3.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| OVERALL LENGTH | 2.500 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING METHOD | THREADED BUSHING |
| NOMINAL THREAD SIZE | 0.750 INCHES SINGLE PRESSURE CONNECTION |
| NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| OPERATING TEMP RATING | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
| OUTSIDE DIAMETER | 0.750 INCHES NOMINAL SINGLE CONNECTION |
| OVERALL DIAMETER | 1.125 INCHES NOMINAL |
| PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| PRESSURE SWITCH TYPE | GAGE |
| PROOF PRESSURE | 200.00 POUNDS PER SQUARE INCH |
| SENSING ELEMENT BURST PRESSURE | 350.00 POUNDS PER SQUARE INCH |
| STYLE DESIGNATOR | CYLINDRICAL |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| THREAD CLASS | 3A SINGLE PRESSURE CONNECTION |
| THREAD LENGTH | 0.642 INCHES MINIMUM AND 0.672 INCHES MAXIMUM SINGLE PRESSURE CONNECTION |
| THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |
| THREAD SERIES DESIGNATOR | UNF SINGLE THREADED BUSHING |
| WIDTH ACROSS FLATS | 1.250 INCHES NOMINAL |