| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CONTACT STIMULUS RATING | 2.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND 7.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 5.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| FEATURES PROVIDED | ELECTRICAL BOX CONNECTOR |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 160.0 FAHRENHEIT MAXIMUM |
| OVERALL LENGTH | 2.500 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING METHOD | INLET CONNECTION |
| NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| PRESSURE SWITCH TYPE | GAGE |
| WIDTH ACROSS FLATS | 0.750 INCHES NOMINAL |
| STYLE DESIGNATOR | CYLINDRICAL |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| THREAD CLASS | 3A SINGLE PRESSURE CONNECTION |
| THREAD LENGTH | 0.438 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
| THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
| THREAD SERIES DESIGNATOR | ACME C SINGLE PRESSURE CONNECTION |