| BODY LENGTH | 1.510 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 270.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 280.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 25.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 35.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FEATURES PROVIDED | INTERNALLY GROUNDED |
| OPERATING TEMP RATING | -245.0 CELSIUS MINIMUM AND 275.0 FAHRENHEIT MAXIMUM |
| OVERALL LENGTH | 2.386 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | THREADED BUSHING |
| NOMINAL THREAD SIZE | 0.375 INCHES SINGLE THREADED BUSHING |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| WIDTH ACROSS FLATS | 0.688 INCHES NOMINAL |
| STYLE DESIGNATOR | PLUG |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | QUICK DISCONNECT, MALE |
| THREAD LENGTH | 0.525 INCHES NOMINAL SINGLE THREADED BUSHING |
| THREAD SERIES DESIGNATOR | PTF-SAE SHORT SINGLE THREADED BUSHING |
| THREAD QUANTITY PER INCH | 18 SINGLE THREADED BUSHING |