| ELECTRICAL CONNECTION TYPE | CABLE |
| ACTUATION METHOD | BUOYANCY |
| AIRCRAFT FUEL FOR WHICH DESIGNED | SPECIFIC |
| AIRCRAFT FUEL GRADE SPECIFIC GRAVITY RATING | NOT RATED,0.850 AT 15.6/15.6 DEG C MAX,0.845 AT 36 DEG API MAX SP GR 0.739 AT 60 DEG API MIN SP GR |
| AIRCRAFT FUEL GRADE SPECIFICATION | MTL-F-5572,MIL-F-5616,MIL-F-5624 |
| AIRCRAFT FUEL GRADE | 80,91/96,100/130,115/145; JP-1; JP-3,JP-4,JP-5 |
| CONTACT ARRANGEMENT | SPST,NORMALLY,OPEN |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES NOMINAL LOAD |
| FLOAT AND CONTACT POSITIONS | FLOAT DOWN, CONTACTS OPEN |
| FLOAT EFFECTIVE TRAVEL | 0.500 INCHES NOMINAL |
| FLOAT QUANTITY | 1 |
| LIQUID TYPE FOR WHICH DESIGNED | AIRCRAFT FUEL |
| OVERALL DIAMETER | 1.375 INCHES NOMINAL |
| OVERALL LENGTH | 9.120 INCHES NOMINAL |
| MOUNTING POSITION | VERTICAL |
| MOUNTING METHOD | CLAMP |
| OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 160.0 FAHRENHEIT MAXIMUM |
| POWER CABLE LENGTH | 36.000 INCHES NOMINAL |
| RELAY | NOT INCLUDED |
| TANK INSERTION LENGTH | 7.000 INCHES MAXIMUM |