| ELECTRICAL CONNECTION TYPE | CONNECTOR RECEPTACLE |
| ACTUATION METHOD | BUOYANCY |
| AIRCRAFT FUEL GRADE SPECIFIC GRAVITY RATING | 0.845 AT 15.6 DEG C,MAX SP GR |
| AIRCRAFT FUEL FOR WHICH DESIGNED | SPECIFIC |
| AIRCRAFT FUEL GRADE | 80/87,91/96,100/130,115/145 AND JP-4,JP-5 |
| AIRCRAFT FUEL GRADE SPECIFICATION | MIL-G-5572C AND MIL-J-5624F |
| CONNECTOR IDENTIFICATION | GS02-14S-7P-001 |
| CONNECTOR MANUFACTURER CODE | 71648 |
| CONTACT ARRANGEMENT | SPDT,NORMALLY CLOSED |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES NOMINAL LOAD |
| DC VOLTAGE RATING | 28.0 VOLTS NOMINAL LOCATION NOT OTHERWISE SPECIFIED |
| FLOAT AND CONTACT POSITIONS | FLOAT DOWN, CONTACTS CLOSED |
| FLOAT EFFECTIVE TRAVEL | 0.750 INCHES MINIMUM AND 1.250 INCHES MAXIMUM |
| FLOAT QUANTITY | 1 |
| LIQUID TYPE FOR WHICH DESIGNED | AIRCRAFT FUEL |
| OVERALL DIAMETER | 4.610 INCHES NOMINAL |
| OVERALL LENGTH | 10.280 INCHES NOMINAL |
| MOUNTING DIMENSIONS | MTD BY SIX 0.320 IN. DIA HOLES EQUALLY SPACED ON A 2 IN. RADIUS |
| MOUNTING POSITION | VERTICAL |
| MOUNTING METHOD | FLANGE |
| OPERATING TEMP RATING | -85.0 FAHRENHEIT MINIMUM AND 160.0 FAHRENHEIT MAXIMUM |
| RELAY | NOT INCLUDED |
| TANK INSERTION LENGTH | 8.530 INCHES MAXIMUM |