| BULB DIAMETER | 0.250 INCHES NOMINAL |
| BULB LENGTH | 4.750 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 84.000 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT KNOB |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +150.00 TO 250.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 DC AT SEA LEVEL THIRD VOLTAGE |
| FEATURES PROVIDED | TUBING END SEAL CONNECTION |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 3.375 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.438 INCHES NOMINAL |
| OVERALL HEIGHT | 5.968 INCHES NOMINAL |
| OVERALL LENGTH | 5.875 INCHES NOMINAL |
| OVERALL WIDTH | 3.375 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| MOUNTING METHOD | BASE |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| SPECIAL FEATURES | INCL MANUALRESET BUTTON AND PILOT LIGHT |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | THREADED STUD |