| BULB DIAMETER | 0.375 INCHES NOMINAL |
| BULB LENGTH | 4.188 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 120.000 INCHES NOMINAL |
| CONTACT ADJUSTMENT RANGE | -30.00 TO 20.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
| CONTACT LOAD CURRENT RATING | 1.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 8.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL SECOND VOLTAGE |
| MOUNTING METHOD | BRACKET(S) |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| SPECIAL FEATURES | PERMANENT MAGNET INSTALLED TO PREVENT EXCESSIVE ARCING AT CONTACTS |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | TAB W/SCREW |