| BODY DIAMETER | 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
| BODY LENGTH | 3.562 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | -100.00 TO 300.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00 TO 300.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 0.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 120.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 5.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL THIRD VOLTAGE |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OPERATING TEMP RATING | -100.0 FAHRENHEIT MINIMUM AND 1000.0 FAHRENHEIT MAXIMUM |
| OVERALL DIAMETER | 1.250 INCHES NOMINAL |
| OVERALL LENGTH | 4.188 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS |
| MOUNTING FACILITY CIRCLE RADIUS | 0.625 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE(S) |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.221 INCHES NOMINAL |
| STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TAB W/SCREW |