| ACTUATOR DIAMETER | 0.050 INCHES NOMINAL0.050 INCHES NOMINAL |
| ACTUATOR HEIGHT | 0.349 INCHES MINIMUM AND 0.349 INCHES MINIMUM AND 0.369 INCHES MAXIMUM0.369 INCHES MAXIMUM |
| ACTUATOR POSITION-ACTION RELATIONSHIP | UP POSITION MAINTAINED AND UP POSITION MAINTAINED AND DOWN POSITION MAINTAINED AND DOWN POSITION MAINTAINED AND CENTER POSITION MAINTAINEDCENTER POSITION MAINTAINED |
| ACTUATOR STYLE | ROUNDROUND |
| BODY HEIGHT | 0.406 INCHES MAXIMUM0.406 INCHES MAXIMUM |
| BODY LENGTH | 0.490 INCHES MINIMUM AND 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM0.510 INCHES MAXIMUM |
| BODY STYLE | BUSHING MOUNTBUSHING MOUNT |
| BODY WIDTH | 0.490 INCHES MINIMUM AND 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM0.510 INCHES MAXIMUM |
| BUSHING LENGTH | 0.375 INCHES MINIMUM AND 0.375 INCHES MINIMUM AND 0.385 INCHES MAXIMUM0.385 INCHES MAXIMUM |
| CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.000 AMPERES RESISTIVE DC AND 5.000 AMPERES RESISTIVE AC |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOFDUSTPROOF |
| INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
| MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 115.0 AC AND 29.0 DC29.0 DC |
| MOUNTING METHOD | THREADED BUSHINGTHREADED BUSHING |
| NOMINAL THREAD SIZE | 0.438 INCHES0.438 INCHES |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, THREE POSITIONS MAINTAINED SINGLE SWITCH UNIT |
| TERMINAL TYPE AND QUANTITY | 6 PIN |
| THREAD CLASS | 2A2A |
| THREAD QUANTITY PER INCH | 3232 |
| THREAD SERIES DESIGNATOR | UN |