| BODY HEIGHT | 0.216 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 160.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 190.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | THREADED STUD(S) |
| NOMINAL THREAD SIZE | 0.112 INCHES ALL THREADED STUD |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| OPERATING TEMP RATING | -30.0 FAHRENHEIT MINIMUM AND 350.0 FAHRENHEIT MAXIMUM |
| OVERALL DIAMETER | 0.215 INCHES NOMINAL |
| OVERALL HEIGHT | 0.614 INCHES NOMINAL |
| SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | DISC |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THREAD CLASS | 2A ALL THREADED STUD |
| THREAD LENGTH | 0.187 INCHES NOMINAL ALL THREADED STUD |
| THREAD QUANTITY PER INCH | 40 ALL THREADED STUD |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) ALL THREADED STUD |