| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +0.00 TO 20.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD AND 125.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 5.125 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
| OVERALL HEIGHT | 3.969 INCHES NOMINAL |
| OVERALL LENGTH | 5.625 INCHES NOMINAL |
| OVERALL WIDTH | 4.219 INCHES NOMINAL |
| MOUNTING METHOD | BRACKET |
| NOMINAL THREAD SIZE | 0.4375 INCHES SINGLE PRESSURE CONNECTION |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| TERMINAL TYPE | WIRE LEAD |
| THREAD SERIES DESIGNATOR | UNF ALL PRESSURE CONNECTION |
| THREAD QUANTITY PER INCH | 20 ALL PRESSURE CONNECTION |