| BODY HEIGHT | 0.290 INCHES MAXIMUM |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 145.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 135.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | THREADED STUD(S) |
| NOMINAL THREAD SIZE | 0.138 INCHES ALL THREADED STUD |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| OVERALL DIAMETER | 0.640 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.597 INCHES MAXIMUM |
| STYLE DESIGNATOR | DISC |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TAB, SOLDER LUG |
| THREAD CLASS | 2A ALL THREADED STUD |
| THREAD LENGTH | 0.187 INCHES NOMINAL ALL THREADED STUD |
| THREAD QUANTITY PER INCH | 32 ALL THREADED STUD |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) ALL THREADED STUD |