5961-00-409-3499 SEMICONDUCTOR DEVICE,DIODE Index 5950-00-409-3501 COIL,ELECTRICAL

National Stock Number:
5930-00-409-3500

Federal Supply Class:
5930

National Item Identification Number:
004093500

Description:
SWITCH,ROTARY

Detail:
A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).


Manufacturer Information:
121908LA82121ELECTRO SWITCH CORP.
R903400810097520BASLER ELECTRIC CO


Techincal Specification:
CONTACT LOAD CURRENT RATING10.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
CONTACT SWITCHING ACTIONMAKES BEFORE BREAKS EACH SECTION FRONT
CONTACT VOLTAGE RATING IN VOLTS125.0 AC AT SEA LEVEL
FEATURES PROVIDEDACTUATOR KNOB
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONEXPLOSION PROOF
INDIVIDUAL SECTION QUANTITY8
KNOB MANUFACTURER CODE82121
KNOB MANUFACTURER PART NUMBER101605A-2A
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS1.641 INCHES NOMINAL SINGLE MOUNTING FACILITY
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.641 INCHES NOMINAL SINGLE MOUNTING FACILITY
POLE QUANTITY1 EACH SECTION FRONT
MOUNTING FACILITY PATTERNFOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING METHODTHREADED HOLE(S) SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE0.190 INCHES SINGLE MOUNTING FACILITY
OPERATING TEMP RANGE-65.0 TO 85.0 CELSIUS
OVERALL HEIGHT2.500 INCHES NOMINAL
OVERALL LENGTH4.781 INCHES NOMINAL
OVERALL WIDTH2.406 INCHES NOMINAL
SHAFT DIAMETER0.250 INCHES NOMINAL SINGLE ACTUATOR
SHAFT LENGTH1.125 INCHES NOMINAL SINGLE ACTUATOR
SHAFT TYPEROUND SINGLE ACTUATOR
STYLE DESIGNATORTAP, CIRCUIT SELECTOR
SWITCH ACTUATOR INDEXING POSITION QUANTITY4 SINGLE ACTUATOR
SWITCH ACTUATOR POSITIONING INCREMENT90.0 DEGREES SINGLE ACTUATOR
SWITCH ACTUATOR STOP DEVICE TYPEFIXED STOP SINGLE ACTUATOR
SWITCH CONTACT BASIC DESIGNNONPILE-UP SYMMETRICAL
TERMINAL TYPESCREW
THREAD CLASS2A SINGLE MOUNTING FACILITY
THREAD QUANTITY PER INCH24 SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
THROW QUANTITY4 EACH SECTION FRONT