SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
837-A3A01121ROCKWELL AUTOMATION, INC.
837AC11FMC01121ROCKWELL AUTOMATION, INC.


Techincal Specification:
STYLE DESIGNATORRECTANGULAR
OVERALL LENGTH2.562 INCHES NOMINAL
OVERALL HEIGHT5.250 INCHES NOMINAL
OVERALL WIDTH3.250 INCHES NOMINAL
BODY HEIGHT4.625 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT ADJUSTABLE AND
ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE25.00 TO 125.00 ACTUATION POINT DEGREES FAHRENHEIT AND
25.00 TO 125.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPEINTERNAL DEACTUATION POINT SCREW AND
INTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATING2.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND
18.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS600.0 AC AT SEA LEVEL FIRST VOLTAGE
240.0 AC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ60.0 SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
OPERATING TEMP RATING160.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDGAS
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH72.0 INCHES NOMINAL
BULB LENGTH8.500 INCHES NOMINAL
BULB DIAMETER0.375 INCHES NOMINAL
TERMINAL TYPETAB W/SCREW
MOUNTING METHODBASE AND
UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL
MOUNTING FACILITY PATTERNTWO POSITION DIAGONAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.000 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS2.000 INCHES NOMINAL
FEATURES PROVIDEDELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONGENERAL PURPOSE-NEMA TYPE 1