| BULB DIAMETER | 0.375 INCHES NOMINAL |
| BULB LENGTH | 3.063 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 96.000 INCHES NOMINAL |
| CONTACT ADJUSTMENT RANGE | -30.00 TO 30.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 12.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 18.4 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 2.3 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| OVERALL HEIGHT | 2.906 INCHES NOMINAL |
| OVERALL LENGTH | 5.453 INCHES NOMINAL |
| OVERALL WIDTH | 4.453 INCHES NOMINAL |
| MOUNTING METHOD | BRACKET(S) |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | TAB W/SCREW |