| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION FRONT |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL |
| FEATURES PROVIDED | ACTUATOR KNOB |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
| INDIVIDUAL SECTION QUANTITY | 15 |
| KNOB MANUFACTURER CODE | 80064 |
| KNOB MANUFACTURER PART NUMBER | 9000S6202-73075-1 |
| MOUNTING FACILITY CIRCLE RADIUS | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | FOUR POSITION CIRCULAR SINGLE MOUNTING FACILITY |
| MOUNTING METHOD | BRACKET(S) SINGLE MOUNTING FACILITY |
| NONDEFINITIVE SPEC/STD DATA | S3JR15 TYPE |
| OVERALL DIAMETER | 3.750 INCHES NOMINAL |
| POLE QUANTITY | 1 EACH SECTION FRONT |
| SHAFT LENGTH | 1.094 INCHES NOMINAL SINGLE ACTUATOR |
| SHAFT TYPE | RECTANGULAR/SQUARE, THREADED HOLE SINGLE ACTUATOR |
| SWITCH ACTUATOR INDEXING POSITION QUANTITY | 8 SINGLE ACTUATOR |
| SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| TERMINAL TYPE | TAB W/SCREW |
| TEST DATA DOCUMENT | 81349-MIL-S-21604 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THROW QUANTITY | 7 EACH SECTION FRONT |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL SINGLE MOUNTING FACILITY |