| ELECTRICAL CONNECTION TYPE | CABLE |
| ACTUATION METHOD | BUOYANCY |
| AIRCRAFT FUEL FOR WHICH DESIGNED | SPECIFIC |
| AIRCRAFT FUEL GRADE SPECIFIC GRAVITY RATING | NOT RATED |
| AIRCRAFT FUEL GRADE SPECIFICATION | MIL-G-5572,MIL-J-5624,MIL-G-3056 |
| AIRCRAFT FUEL GRADE | JP-5,JP-3,JP-4 |
| CONTACT ARRANGEMENT | SPST,NORMALLY OPEN |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES RESISTIVE LOAD |
| DC VOLTAGE RATING | 28.0 VOLTS NOMINAL FIRST OPERATING POWER RQMT |
| FLOAT EFFECTIVE TRAVEL | 0.140 INCHES MINIMUM AND 0.350 INCHES MAXIMUM |
| FLOAT QUANTITY | 1 |
| FSC APPLICATION DATA | SWITCH,FLOAT,LIQUID LEVEL,EXCEPT ENGINE |
| LIQUID TYPE FOR WHICH DESIGNED | AIRCRAFT FUEL |
| OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 160.0 FAHRENHEIT MAXIMUM |
| OVERALL HEIGHT | 3.797 INCHES NOMINAL |
| OVERALL LENGTH | 2.609 INCHES NOMINAL |
| OVERALL WIDTH | 1.380 INCHES NOMINAL |
| MOUNTING DIMENSIONS | MTG BY 1/2-20 UNF THD CONNECTION |
| MOUNTING METHOD | THREAD |
| MOUNTING POSITION | VERTICAL |
| POWER CABLE LENGTH | 24.000 INCHES NOMINAL |
| RELAY | NOT INCLUDED |
| TANK INSERTION LENGTH | 3.360 INCHES MAXIMUM |