| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
| CONTACT VOLTAGE RATING IN VOLTS | 120.0 DC AT SEA LEVEL |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | DUMMY CONTACT |
| INDIVIDUAL SECTION QUANTITY | 3 |
| OVERALL LENGTH | 1.656 INCHES NOMINAL |
| OVERALL WIDTH | 2.188 INCHES MINIMUM AND 2.250 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING METHOD | BRACKET(S) AND UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| OVERALL HEIGHT | 2.281 INCHES MAXIMUM |
| SHAFT DIAMETER | 0.219 INCHES NOMINAL SINGLE ACTUATOR |
| SHAFT LENGTH | 0.250 INCHES MINIMUM AND 0.312 INCHES MAXIMUM SINGLE ACTUATOR |
| SHAFT TYPE | ROUND SINGLE ACTUATOR |
| SPECIFICATION/STANDARD DATA | 81349-MIL-DTL-15291/3 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | TAP, CIRCULAR FRAME |
| SWITCH ACTUATOR INDEXING POSITION QUANTITY | 4 SINGLE ACTUATOR |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
| TERMINAL TYPE | TAB W/SCREW |
| TEST DATA DOCUMENT | 81349-MIL-DTL-15291 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |