| CONTACT LOAD CURRENT RATING | 400.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL |
| FIRST FLAT LENGTH | 0.430 INCHES MINIMUM AND 0.450 INCHES MAXIMUM SINGLE ACTUATOR |
| FLAT HEIGHT | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM SINGLE ACTUATOR |
| INDIVIDUAL SECTION QUANTITY | 1 |
| OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
| OVERALL HEIGHT | 1.300 INCHES MINIMUM AND 1.320 INCHES MAXIMUM |
| OVERALL LENGTH | 1.620 INCHES MINIMUM AND 1.640 INCHES MAXIMUM |
| OVERALL WIDTH | 1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
| MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
| NONTURN DEVICE RADIUS | 0.520 INCHES MINIMUM AND 0.540 INCHES MAXIMUM AT 3:00 OCLOCK |
| NONTURN DEVICE TYPE | TAB AT 3:00 OCLOCK |
| SHAFT FLAT/SLOT ANGULAR LOCATION | 0.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
| SHAFT DIAMETER | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM SINGLE ACTUATOR |
| SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
| SHAFT LENGTH | 0.870 INCHES MINIMUM AND 0.890 INCHES MAXIMUM SINGLE ACTUATOR |
| SPECIAL FEATURES | SWITCH IN POSITION NO. 3 SPRING RETURN FROM OTHER POSITIONS TO CENTER. THERE SHALL BE DETENT FEEL AT POSITIONS 2,3,AND 4 |
| STYLE DESIGNATOR | CIRCULAR WAFER, BUSHING MOUNT |
| SWITCH ACTUATOR INDEXING POSITION QUANTITY | 5 SINGLE ACTUATOR |
| SWITCH ACTUATOR POSITIONING INCREMENT | 30.0 DEGREES SINGLE ACTUATOR |
| SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TEST DATA DOCUMENT | 06481-900027-56 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD LENGTH | 0.370 INCHES MINIMUM AND 0.390 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |