| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 45.4 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 0.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 0.04 ACTUATION POINT MINIMUM GALLONS PER MINUTE AND 0.06 ACTUATION POINT MAXIMUM GALLONS PER MINUTE |
| CONTACT VOLTAGE RATING IN VOLTS | 220.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FEATURES PROVIDED | AUTOMATIC RESET |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL HEIGHT | 1.000 INCHES NOMINAL |
| OVERALL LENGTH | 3.813 INCHES NOMINAL |
| OVERALL WIDTH | 2.000 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING METHOD | LINE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| TERMINAL TYPE | WIRE LEAD |