| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | ERR-030 OR ERR-030 |
| BODY HEIGHT | 35.0 MILLIMETERS NOMINAL |
| BODY LENGTH | 46.0 MILLIMETERS MAXIMUM |
| BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| BODY WIDTH | 20.0 MILLIMETERS MAXIMUM |
| BUSHING LENGTH | 7.2 MILLIMETERS MAXIMUM |
| CASE MATERIAL | PLASTIC |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 12.7 MILLIMETERS NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 15.2 MILLIMETERS NOMINAL |
| FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES AC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 AC ALL LOCATIONS |
| POLE QUANTITY | 3 |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| NOMINAL THREAD SIZE | 12.0 MILLIMETERS |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS |
| RESET METHOD | MANUAL |
| TERMINAL TYPE AND QUANTITY | 6 SCREW |
| THREAD SERIES DESIGNATOR | ISO M |
| THREAD PITCH IN MILLIMETERS | 0.75 |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 ALL LOCATIONS |