| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| BODY LENGTH | 55,5 MILLIMETERS MAXIMUM |
| BODY STYLE | SINGLE POLE TYPE |
| BODY WIDTH | 19,0 MILLIMETERS MAXIMUM |
| CASE MATERIAL | PLASTIC |
| CIRCUIT PROTECTION TYPE | OVERCURRENT |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100,0 AMPERES DC |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 6000 DC |
| POLE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 61,5 MILLIMETERS MAXIMUM |
| NOMINAL THREAD SIZE | 12 MILLIMETERS |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 28,0 DC |
| RESET METHOD | MANUAL |
| TERMINAL TYPE AND QUANTITY | 2 SCREW |
| THREAD SERIES DESIGNATOR | ISO M |
| THREAD PITCH IN MILLIMETERS | 1,0 |
| TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY |
| TRIP RELEASE METHOD | THERMAL-MAGNETIC |