| BODY DIAMETER | 0.820 INCHES NOMINAL |
| BODY STYLE | SINGLE POLE TYPE |
| BUSHING LENGTH | 0.570 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.100 INCHES NOMINAL |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 36.0 DC ALL LOCATIONS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT BREAKER, 5 AMP |
| MATERIAL | PLASTIC CASE |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15.0 DC ALL LOCATIONS |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 SLOT |
| MOUNTING SLOT WIDTH | 0.820 INCHES NOMINAL |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.350 INCHES NOMINAL |
| POLE QUANTITY | 2 |
| RESET METHOD | AUTOMATIC |
| TRIP RELEASE AMBIENT TEMP RATING | 40.0 CELSIUS NOMINAL ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
| TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 100.0 ALL LOCATIONS |
| TERMINAL TYPE AND QUANTITY | 1 BUS BAR |