| ACTUATOR FUNCTION | RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| BODY LENGTH | 0.780 INCHES MAXIMUM |
| BODY STYLE | SINGLE POLE TYPE |
| BODY WIDTH | 0.700 INCHES NOMINAL |
| BUSHING LENGTH | 0.175 INCHES MINIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.700 INCHES MINIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 28.0 DC SINGLE LOCATION |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| MATERIAL | PLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 AC AND 800.0 DC SINGLE LOCATION |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING WITH PANEL SEAL |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.852 INCHES MAXIMUM |
| POLE QUANTITY | 1 |
| RESET METHOD | MANUAL |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3600.000 MINIMUM AT 115 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |
| TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |