6910-01-329-4880 LUNG,RECORDING,RESUSCITATION TRA Index 5925-01-329-4882 CIRCUIT BREAKER

National Stock Number:
5925-01-329-4881

Federal Supply Class:
5925

National Item Identification Number:
013294881

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
1771-101558723KENDRION (SHELBY) INC.
1771-103058723KENDRION (SHELBY) INC.
T10346375755DEERE & COMPANY
T103463Z0944HITACHI CONSTRUCTION MACHINERY AUSTRALIA PTY LTD
T103463ZB955VANDERFIELD PTY LTD


Techincal Specification:
ARC QUENCHING METHODMAGNETIC BLOWOUT
BODY STYLERECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
FRAGILITY FACTORMODERATELY RUGGED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
OVERALL HEIGHT0.400 INCHES NOMINAL
OVERALL LENGTH1.320 INCHES NOMINAL
OVERALL WIDTH0.840 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS12.0 DC SINGLE LOCATION
POLE QUANTITY1
RESET METHODAUTOMATIC
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY2 QUICK DISCONNECT, MALE
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICINSTANTANEOUS SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION