| AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 115.0 AC NOMINAL SINGLE LOCATION |
| BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE SINGLE LOCATION |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OVERALL HEIGHT | 1.200 INCHES MAXIMUM |
| OVERALL LENGTH | 4.260 INCHES MAXIMUM |
| OVERALL WIDTH | 3.250 INCHES MAXIMUM |
| MATERIAL | PLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC SINGLE LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3600.0 AC SINGLE LOCATION |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC SINGLE LOCATION |
| POLE QUANTITY | 1 |
| RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS | 115.0 AC |
| RESET METHOD | ELECTRIC |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.167 INCHES MINIMUM AND 0.177 INCHES MAXIMUM |
| TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
| TRIP RELEASE AMBIENT TEMP RATING | 71.0 CELSIUS NOMINAL SINGLE LOCATION |
| TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
| TRIP RELEASE DUTY CYCLE | CONTINUOUS SINGLE LOCATION |
| TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |