| ARC QUENCHING METHOD | AIRAIR |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPERECTANGULAR DIMENSIONAL ENVELOPE |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OVERALL HEIGHT | 3.250 INCHES MAXIMUM3.250 INCHES MAXIMUM |
| OVERALL LENGTH | 4.260 INCHES NOMINAL4.260 INCHES NOMINAL |
| OVERALL WIDTH | 3.690 INCHES NOMINAL3.690 INCHES NOMINAL |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60.0 AMPERES AC AND 60.0 AMPERES DC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 50000.0 AC AND 50000.0 DC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S)4 UNTHREADED HOLE(S) |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC AND 30.0 DC ALL LOCATIONS |
| POLE QUANTITY | 33 |
| RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS | 115.0 AC |
| RESET METHOD | MANUAL |
| SPECIFICATION/STANDARD DATA | 81349--83383/04-10 GOVERNMENT SPECIFICATION |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.167 INCHES MINIMUM AND 0.167 INCHES MINIMUM AND 0.177 INCHES MAXIMUM0.177 INCHES MAXIMUM |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 115.0 AC AND 28.0 DC |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 3.0 AC AND 1.5 DC |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE THREE |
| TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
| TEST DATA DOCUMENT | 81349-MIL-C-83383 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 13.000 MINIMUM AT 200 PCT AND 80.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| TRIP RELEASE AMBIENT TEMP RATING | 25.0 CELSIUS NOMINAL ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS |