| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| ARC QUENCHING METHOD | AIRAIR |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| BODY LENGTH | 1.531 INCHES MINIMUM AND 1.531 INCHES MINIMUM AND 1.562 INCHES MAXIMUM1.562 INCHES MAXIMUM |
| BODY STYLE | SINGLE POLE TYPESINGLE POLE TYPE |
| BODY WIDTH | 0.594 INCHES MINIMUM AND 0.594 INCHES MINIMUM AND 0.625 INCHES MAXIMUM0.625 INCHES MAXIMUM |
| BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM0.380 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES MINIMUM AND 0.875 INCHES MINIMUM AND 0.906 INCHES MAXIMUM0.906 INCHES MAXIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC SINGLE LOCATION |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| MATERIAL | PLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC SINGLE LOCATION |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING1 THREADED BUSHING |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.669 INCHES MINIMUM AND 1.669 INCHES MINIMUM AND 1.700 INCHES MAXIMUM1.700 INCHES MAXIMUM |
| NOMINAL THREAD SIZE | 0.375 INCHES |
| POLE QUANTITY | 11 |
| RESET METHOD | MANUAL |
| TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
| TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| UNPACKAGED UNIT WEIGHT | 50.0 GRAMS NOMINAL |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-39019/2 GOVERNMENT SPECIFICATION |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 0.5 AC AND 0.5 DC |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 50.0 DC |
| TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
| TEST DATA DOCUMENT | 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THREAD SERIES DESIGNATOR | UNEF |
| THREAD QUANTITY PER INCH | 3232 |