| AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 115.0 AC NOMINAL ALL LOCATIONS |
| BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE ALL LOCATIONS |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OVERALL HEIGHT | 4.250 INCHES NOMINAL |
| OVERALL LENGTH | 3.688 INCHES NOMINAL |
| OVERALL WIDTH | 3.250 INCHES NOMINAL |
| MATERIAL | PLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 216.0 AC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS |
| POLE QUANTITY | 3 |
| RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS | 115.0 AC |
| RESET METHOD | ELECTRIC |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.172 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
| TRIP RELEASE AMBIENT TEMP RATING | -54.0 CELSIUS MINIMUM AND 71.0 CELSIUS MAXIMUM ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
| TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
| TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | 60.000 MAXIMUM ALL LOCATIONS |