5330-01-108-3052 GASKET Index 5895-01-108-3055 OSCILLATOR RADIO FR

National Stock Number:
5925-01-108-3053

Federal Supply Class:
5925

National Item Identification Number:
011083053

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
170-009-15076374SAFRAN ELECTRICAL & POWER USA, LLC
170-009-15081640SAFRAN POWER USA, LLC
220-10843-181205THE BOEING COMPANY


Techincal Specification:
BODY LENGTH1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
BODY STYLESINGLE POLE TYPE
BODY WIDTH1.000 INCHES MAXIMUM
BUSHING LENGTH0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.437 INCHES NOMINAL
FREQUENCY IN HERTZ60.0 SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE150.0 AMPERES DC SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE2.250 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS36.0 DC SINGLE LOCATION
POLE QUANTITY1
RESET METHODMANUAL
TERMINAL TYPE AND QUANTITY2 TAB W/SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT15.000 MINIMUM AT 200 PCT AND 70.000 MAXIMUM AT 200 PCT AND 2.000 MINIMUM AT 400 PCT AND 12.000 MAXIMUM AT 400 PCT AND 1.000 MINIMUM AT 600 PCT AND 5.000 MAXIMUM AT 600 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING-40.0 CELSIUS MINIMUM AND 71.0 CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION