| ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLEAT EACH POLE |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUTMAGNETIC BLOWOUT |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM1 ALARM |
| BODY LENGTH | 5.768 INCHES MINIMUM AND 5.768 INCHES MINIMUM AND 5.832 INCHES MAXIMUM5.832 INCHES MAXIMUM |
| BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE |
| BODY WIDTH | 2.038 INCHES MINIMUM AND 2.038 INCHES MINIMUM AND 2.102 INCHES MAXIMUM2.102 INCHES MAXIMUM |
| BOSS HEIGHT | 0.209 INCHES MINIMUM AND 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM0.229 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.515 INCHES MINIMUM AND 3.515 INCHES MINIMUM AND 3.579 INCHES MAXIMUM3.579 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.016 INCHES MINIMUM AND 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM1.036 INCHES MAXIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.016 INCHES MINIMUM AND 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM1.036 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.718 INCHES MINIMUM AND 2.718 INCHES MINIMUM AND 2.782 INCHES MAXIMUM2.782 INCHES MAXIMUM |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKEDONE AND TWO LINKED |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANTMOISTURE RESISTANT |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 270.0 DC ALL LOCATIONS270.0 DC ALL LOCATIONS |
| MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE2 TOGGLE |
| MATERIAL | PLASTIC CASEPLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC ALL LOCATIONS5.0 AMPERES DC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC ALL LOCATIONS5000.0 DC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) AND 4 THREADED HOLE(S) AND 4 SLOT4 SLOT |
| MOUNTING SLOT WIDTH | 0.164 INCHES NOMINAL0.164 INCHES NOMINAL |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.172 INCHES MINIMUM AND 3.172 INCHES MINIMUM AND 3.296 INCHES MAXIMUM3.296 INCHES MAXIMUM |
| NOMINAL THREAD SIZE | 0.138 INCHES0.138 INCHES |
| POLE QUANTITY | 22 |
| RESET METHOD | MANUALMANUAL |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.800 MINIMUM AT 200 PCT AND 0.800 MINIMUM AT 200 PCT AND 2.500 MAXIMUM AT 200 PCT ALL LOCATIONS2.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS |
| TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONSMAGNETIC ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS125.0 ALL LOCATIONS |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONEINTERNAL AT POLE ONE |
| SWITCH TERMINAL TYPE | TURRETTURRET |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 240.0 AC AND 240.0 AC AND 50.0 DC50.0 DC |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 2.5 AC AND 1.0 DC1.0 DC |
| TERMINAL TYPE AND QUANTITY | 4 THREADED STUD4 THREADED STUD |
| THREAD QUANTITY PER INCH | 3232 |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC) |