5925-01-043-3152 CIRCUIT BREAKER Index 5330-01-043-3154 SEAL,PLAIN ENCASED

National Stock Number:
5925-01-043-3153

Federal Supply Class:
5925

National Item Identification Number:
010433153

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
53-121-4-MG374193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
9176315-318876U S ARMY AVIATION AND MISSILE COMMAND
9176315-38S201RIVERSIDE COMPONENT SUPPLY CO


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESETTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLEAT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM1 ALARM
BODY LENGTH3.719 INCHES NOMINAL3.719 INCHES NOMINAL
BODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH3.063 INCHES NOMINAL3.063 INCHES NOMINAL
BOSS HEIGHT0.156 INCHES NOMINAL0.156 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.060 INCHES NOMINAL3.060 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.030 INCHES NOMINAL1.030 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.030 INCHES NOMINAL1.030 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.750 INCHES NOMINAL2.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKEDONE, TWO, AND THREE LINKED
FRAGILITY FACTORMODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 ALL LOCATIONS400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND FUNGUS RESISTANT AND VIBRATION RESISTANT AND VIBRATION RESISTANT AND HUMIDITY RESISTANT AND HUMIDITY RESISTANT AND SALT SPRAY PROOFSALT SPRAY PROOF
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS416.0 AC ALL LOCATIONS416.0 AC ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE3 TOGGLE
MATERIALPLASTIC CASEPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE7.5 AMPERES AC ALL LOCATIONS7.5 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1500.0 AC ALL LOCATIONS1500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE(S)6 THREADED HOLE(S)
MOUNTING SURFACE TO TERMINAL END DISTANCE3.120 INCHES MINIMUM AND 3.120 INCHES MINIMUM AND 3.240 INCHES MAXIMUM3.240 INCHES MAXIMUM
NOMINAL THREAD SIZE0.138 INCHES0.138 INCHES
POLE QUANTITY33
PRECIOUS MATERIALSILVERSILVER
PRECIOUS MATERIAL AND LOCATIONTERMINAL SURFACES SILVERTERMINAL SURFACES SILVER
RESET METHODMANUALMANUAL
SPECIAL HANDLING FEATUREMAGNETICMAGNETIC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT20.500 MINIMUM AT 200 PCT AND 20.500 MINIMUM AT 200 PCT AND 80.000 MAXIMUM AT 200 PCT ALL LOCATIONS80.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC ALL LOCATIONSMAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS150.0 ALL LOCATIONS
STORAGE TYPEGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE THREEINTERNAL AT POLE THREE
SWITCH TERMINAL TYPETURRETTURRET
SWITCH VOLTAGE RATING AND TYPE IN VOLTS115.0 AC AND 115.0 AC AND 28.0 DC28.0 DC
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS5.0 AC AND 5.0 AC AND 5.0 DC5.0 DC
TERMINAL TYPE AND QUANTITY6 THREADED STUD6 THREADED STUD
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC)