5925-01-026-5841 CIRCUIT BREAKER Index 5925-01-026-5843 CIRCUIT BREAKER

National Stock Number:
5925-01-026-5842

Federal Supply Class:
5925

National Item Identification Number:
010265842

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
6TC12-282647SENSATA TECHNOLOGIES, INC.
GC885DW226512NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESETTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONEAT POLE ONE
ARC QUENCHING METHODMAGNETIC BLOWOUTMAGNETIC BLOWOUT
BODY LENGTH1.381 INCHES MAXIMUM1.381 INCHES MAXIMUM
BODY STYLESINGLE POLE TYPESINGLE POLE TYPE
BODY WIDTH0.531 INCHES MAXIMUM0.531 INCHES MAXIMUM
BUSHING LENGTH0.375 INCHES NOMINAL0.375 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.531 INCHES NOMINAL1.531 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION
FRAGILITY FACTORMODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 SINGLE LOCATION400.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDVIBRATIONPROOFVIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC SINGLE LOCATION120.0 AC SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL1 PUSH-PULL
MATERIALPLASTIC CASEPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE2.0 AMPERES AC SINGLE LOCATION2.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 AC SINGLE LOCATION2000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE1.669 INCHES NOMINAL1.669 INCHES NOMINAL
NOMINAL THREAD SIZE0.438 INCHES0.438 INCHES
POLE QUANTITY11
RESET METHODMANUALMANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 200 PCT AND 4.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATIONTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0 SINGLE LOCATION135.0 SINGLE LOCATION
UNPACKAGED UNIT WEIGHT62.0 GRAMS NOMINAL62.0 GRAMS NOMINAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY2 SCREW2 SCREW
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNUN