POLE QUANTITY | 1 |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC SINGLE LOCATION |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND |
| TIME DELAY SINGLE LOCATION |
RESET METHOD | MANUAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.300 NOMINAL AT 125 PCT AND |
| 0.060 NOMINAL AT 200 PCT SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
OVERALL LENGTH | 2.600 INCHES NOMINAL |
OVERALL HEIGHT | 0.625 INCHES NOMINAL |
OVERALL WIDTH | 1.500 INCHES NOMINAL |
THREAD SERIES DESIGNATOR | UNEF |
NOMINAL THREAD SIZE | 0.375 INCHES |
THREAD QUANTITY PER INCH | 32 |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
ACTUATOR FUNCTION | RESET |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND |
| EXPLOSION PROOF |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
PRECIOUS MATERIAL | SILVER |