| UNPACKAGED UNIT WEIGHT | 14.800 OUNCES NOMINAL |
| SPECIAL HANDLING FEATURE | MAGNETIC |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 10.0 DC |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE FOUR |
| SWITCH TERMINAL TYPE | PIN |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| BODY LENGTH | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
| BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| BODY WIDTH | 3.015 INCHES MAXIMUM |
| BOSS HEIGHT | 0.150 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.940 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, AND FOUR LINKED |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC THIRD LOCATION |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC FIRST LOCATION |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC FOURTH LOCATION |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC SECOND LOCATION |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES DC FIRST LOCATION |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES DC THIRD LOCATION |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 MILLIAMPERES DC FOURTH LOCATION |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 MILLIAMPERES DC SECOND LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.625 INCHES MAXIMUM |
| POLE QUANTITY | 4 |
| RESET METHOD | MANUAL |
| THREAD QUANTITY PER INCH | 32 |
| THREAD SERIES DESIGNATOR | UNC |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.024 MAXIMUM AT 200 PCT FOURTH LOCATION |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.024 MAXIMUM AT 200 PCT SECOND LOCATION |
| TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS THIRD LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY FOURTH LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
| TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |