5945-00-267-1458 RELAY,HYBRID Index 9515-00-267-1465 SHEET,METAL

National Stock Number:
5925-00-267-1459

Federal Supply Class:
5925

National Item Identification Number:
002671459

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
253502-182577RAYTHEON COMPANY
RRP112R891-281541SENSATA TECHNOLOGIES MARYLAND, INC


Techincal Specification:
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM1 ALARM
AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS29.0 DC MAXIMUM FIRST LOCATION29.0 DC MAXIMUM FIRST LOCATION
BODY STYLERECTANGULAR DIMENSIONAL ENVELOPERECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ400.0 ALL LOCATIONS400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALEDHERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATIONSERIES TRIP SECOND LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP THIRD LOCATIONSERIES TRIP THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP W/DUAL RATING AND REMOTE TRIP FEATURE FIRST LOCATIONSERIES TRIP W/DUAL RATING AND REMOTE TRIP FEATURE FIRST LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
OVERALL HEIGHT2.850 INCHES MAXIMUM2.850 INCHES MAXIMUM
OVERALL LENGTH2.190 INCHES MAXIMUM2.190 INCHES MAXIMUM
OVERALL WIDTH1.515 INCHES MAXIMUM1.515 INCHES MAXIMUM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE20.0 AMPERES AC ALL LOCATIONS20.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS500.0 AC ALL LOCATIONS500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S)4 THREADED HOLE(S)
NOMINAL THREAD SIZE0.138 INCHES0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC ALL LOCATIONS115.0 AC ALL LOCATIONS
POLE QUANTITY33
RESET METHODELECTRICELECTRIC
RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS29.0 DC29.0 DC
SWITCH TERMINAL TYPETAB, SOLDER LUGTAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS28.0 DC28.0 DC
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS1.0 DC1.0 DC
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONEINTERNAL AT POLE ONE
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG AND 2 TAB, SOLDER LUG AND 6 WIRE HOOK6 WIRE HOOK
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC)
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.500 MINIMUM AT 200 PCT AND 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS
TRIP RELEASE DUTY CYCLECONTINUOUS ALL LOCATIONSCONTINUOUS ALL LOCATIONS
TRIP RELEASE METHODMAGNETIC ALL LOCATIONSMAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS125.0 ALL LOCATIONS