5925-00-265-9486 CIRCUIT BREAKER Index 5925-00-265-9488 CIRCUIT BREAKER

National Stock Number:
5925-00-265-9487

Federal Supply Class:
5925

National Item Identification Number:
002659487

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
SK5034TYPEM156302SQUARE D CO CEDAR RAPIDS MFG PLANT
SK5034TYPEM156365SCHNEIDER ELECTRIC USA, INC.


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESETTRIP-RESET
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ60.0 ALL LOCATIONS60.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE1 TOGGLE
OVERALL HEIGHT3.500 INCHES NOMINAL3.500 INCHES NOMINAL
OVERALL LENGTH9.000 INCHES NOMINAL9.000 INCHES NOMINAL
OVERALL WIDTH4.875 INCHES NOMINAL4.875 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC ALL LOCATIONS50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S)4 THREADED HOLE(S)
NOMINAL THREAD SIZE0.138 INCHES0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC FIRST LOCATION120.0 AC FIRST LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC SECOND LOCATION240.0 AC SECOND LOCATION
POLE QUANTITY22
RESET METHODMANUALMANUAL
TERMINAL TYPE AND QUANTITY4 SCREW4 SCREW
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC)
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT252.000 NOMINAL AT 125 PCT AND 252.000 NOMINAL AT 125 PCT AND 20.000 MINIMUM AT 200 PCT AND 20.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT AND 6.000 MINIMUM AT 300 PCT AND 6.000 MINIMUM AT 300 PCT AND 10.000 MAXIMUM AT 300 PCT ALL LOCATIONS10.000 MAXIMUM AT 300 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING75.0 FAHRENHEIT NOMINAL ALL LOCATIONS75.0 FAHRENHEIT NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS
TRIP RELEASE METHODTHERMAL ALL LOCATIONSTHERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 ALL LOCATIONS115.0 ALL LOCATIONS