| ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLEAT EACH POLE |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUTMAGNETIC BLOWOUT |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM1 ALARM |
| BODY LENGTH | 2.480 INCHES MINIMUM AND 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM2.500 INCHES MAXIMUM |
| BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE |
| BODY WIDTH | 2.250 INCHES MAXIMUM2.250 INCHES MAXIMUM |
| BOSS HEIGHT | 0.150 INCHES NOMINAL0.150 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.940 INCHES NOMINAL1.940 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL0.750 INCHES NOMINAL |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM2.070 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL0.750 INCHES NOMINAL |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKEDONE, TWO, AND THREE LINKED |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| FREQUENCY IN HERTZ | 50.0 OR 50.0 OR 60.0 ALL LOCATIONS60.0 ALL LOCATIONS |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SALT SPRAY PROOF AND SHOCK RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND VIBRATION RESISTANT AND FUNGUS RESISTANTFUNGUS RESISTANT |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE3 TOGGLE |
| MATERIAL | PLASTIC CASEPLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS5.0 AMPERES AC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS5000.0 AC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE(S)6 THREADED HOLE(S) |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.475 INCHES NOMINAL2.475 INCHES NOMINAL |
| NOMINAL THREAD SIZE | 3.0 MILLIMETERS3.0 MILLIMETERS |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS250.0 AC ALL LOCATIONS |
| POLE QUANTITY | 33 |
| RESET METHOD | MANUALMANUAL |
| SPECIAL HANDLING FEATURE | MAGNETICMAGNETIC |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 250.0 AC AND 50.0 DC50.0 DC |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 10.0 AC AND 3.0 DC3.0 DC |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONEINTERNAL AT POLE ONE |
| SWITCH TERMINAL TYPE | QUICK DISCONNECT, MALEQUICK DISCONNECT, MALE |
| TERMINAL TYPE AND QUANTITY | 6 THREADED STUD6 THREADED STUD |
| THREAD PITCH IN MILLIMETERS | 0.500.50 |
| THREAD SERIES DESIGNATOR | ISO SISO S |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS |
| TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONSMAGNETIC ALL LOCATIONS |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS115.0 ALL LOCATIONS |
| UNPACKAGED UNIT WEIGHT | 11.100 OUNCES NOMINAL11.100 OUNCES NOMINAL |