5905-00-258-5047 RESISTOR,VARIABLE,NONWIRE WOUND, Index 5925-00-258-5049 TRIPPER,CIRCUIT BREAKER

National Stock Number:
5925-00-258-5048

Federal Supply Class:
5925

National Item Identification Number:
002585048

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
5925002585048A00AME.C.A ETABLISSEMENT CENTRAL DESAPPROVISIONNEMENTS DES FORCES ARMEE
5925002585048SCY13E.C.A ETABLISSEMENT CENTRALD'APPROVISIONNEMENT DES FORCES ARMEE
739243819207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM
S257580212BAE SYSTEMS LAND & ARMAMENTS L.P.
PDLA6082647SENSATA TECHNOLOGIES, INC.


Techincal Specification:
ARC QUENCHING METHODAIR
BODY STYLESINGLE POLE TYPE
BODY WIDTH1.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.062 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.406 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE PROOF
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS32.0 DC SINGLE LOCATION
OVERALL LENGTH3.156 INCHES NOMINAL
MATERIALPLASTIC CASE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS6900.0 DC SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE60.0 AMPERES DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S)
MOUNTING SURFACE TO TERMINAL END DISTANCE1.359 INCHES MAXIMUM
POLE QUANTITY1
RESET METHODAUTOMATIC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT600.000 MINIMUM AT 125 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER0.203 INCHES NOMINAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY2 SCREW


Click here to Register for Free 30-day Trial