| ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLEAT EACH POLE |
| BODY LENGTH | 3.719 INCHES NOMINAL3.719 INCHES NOMINAL |
| BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE |
| BODY WIDTH | 2.031 INCHES NOMINAL2.031 INCHES NOMINAL |
| BOSS HEIGHT | 0.156 INCHES NOMINAL0.156 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.063 INCHES NOMINAL3.063 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.031 INCHES NOMINAL1.031 INCHES NOMINAL |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.031 INCHES NOMINAL1.031 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.750 INCHES NOMINAL2.750 INCHES NOMINAL |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKEDONE AND TWO LINKED |
| FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS50.0 ALL LOCATIONS |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANTMOISTURE RESISTANT |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS250.0 AC ALL LOCATIONS |
| MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE2 TOGGLE |
| MATERIAL | PLASTIC CASEPLASTIC CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS15.0 AMPERES AC ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS1500.0 AC ALL LOCATIONS |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S)4 THREADED HOLE(S) |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.427 INCHES NOMINAL3.427 INCHES NOMINAL |
| NOMINAL THREAD SIZE | 0.138 INCHES0.138 INCHES |
| POLE QUANTITY | 22 |
| RESET METHOD | MANUALMANUAL |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 13.000 MINIMUM AT 150 PCT AND 13.000 MINIMUM AT 150 PCT AND 40.000 MAXIMUM AT 150 PCT AND 40.000 MAXIMUM AT 150 PCT AND 1.000 MINIMUM AT 400 PCT AND 1.000 MINIMUM AT 400 PCT AND 3.000 MAXIMUM AT 400 PCT ALL LOCATIONS3.000 MAXIMUM AT 400 PCT ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS |
| TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONSMAGNETIC-HYDRAULIC ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS125.0 ALL LOCATIONS |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | 10.000 MINIMUM AND 10.000 MINIMUM AND 80.000 MAXIMUM ALL LOCATIONS80.000 MAXIMUM ALL LOCATIONS |
| TERMINAL TYPE AND QUANTITY | 4 THREADED STUD4 THREADED STUD |
| THREAD QUANTITY PER INCH | 3232 |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC) |