| ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONEAT POLE ONE |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUTMAGNETIC BLOWOUT |
| BODY LENGTH | 1.448 INCHES MINIMUM AND 1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM1.510 INCHES MAXIMUM |
| BODY STYLE | SINGLE POLE TYPESINGLE POLE TYPE |
| BODY WIDTH | 0.567 INCHES MINIMUM AND 0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM0.629 INCHES MAXIMUM |
| BUSHING LENGTH | 0.360 INCHES MINIMUM AND 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM0.380 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.870 INCHES MINIMUM AND 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM0.880 INCHES MAXIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION400.0 SINGLE LOCATION |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | EXPLOSION RESISTANT AND EXPLOSION RESISTANT AND FUNGUS RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALEDHERMETICALLY SEALED |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC SINGLE LOCATION115.0 AC SINGLE LOCATION |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE1 TOGGLE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.5 AMPERES AC SINGLE LOCATION1.5 AMPERES AC SINGLE LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 AC SINGLE LOCATION500.0 AC SINGLE LOCATION |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING WITH PANEL SEAL1 THREADED BUSHING WITH PANEL SEAL |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.524 INCHES MINIMUM AND 1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM1.586 INCHES MAXIMUM |
| NOMINAL THREAD SIZE | 0.375 INCHES0.375 INCHES |
| POLE QUANTITY | 11 |
| RESET METHOD | MANUALMANUAL |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.000 MINIMUM AT 200 PCT AND 1.000 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT SINGLE LOCATION3.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION |
| TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATIONMAGNETIC-HYDRAULIC SINGLE LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 SINGLE LOCATION115.0 SINGLE LOCATION |
| UNPACKAGED UNIT WEIGHT | 5.100 OUNCES NOMINAL5.100 OUNCES NOMINAL |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK2 WIRE HOOK |
| THREAD PITCH DIAMETERS | +0.3503 TO 0.3537 INCHES+0.3503 TO 0.3537 INCHES |
| THREAD QUANTITY PER INCH | 3232 |
| THREAD SERIES DESIGNATOR | UNEFUNEF |