5961-00-240-2812 TRANSISTOR Index 5915-00-240-2818 INACTIVE

National Stock Number:
5925-00-240-2814

Federal Supply Class:
5925

National Item Identification Number:
002402814

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
16486419139EASTMAN KODAK CO
PSM-20-N82647SENSATA TECHNOLOGIES, INC.


Techincal Specification:
ACTUATOR FUNCTIONRESETRESET
ACTUATOR POSITION DESIGNATIONAT POLE ONEAT POLE ONE
BODY LENGTH1.312 INCHES NOMINAL1.312 INCHES NOMINAL
BODY STYLESINGLE POLE TYPESINGLE POLE TYPE
BODY WIDTH0.703 INCHES NOMINAL0.703 INCHES NOMINAL
BUSHING LENGTH0.250 INCHES NOMINAL0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.031 INCHES NOMINAL1.031 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION
FRAGILITY FACTORMODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ60.0 SINGLE LOCATION60.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANTMOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS110.0 AC AND 110.0 AC AND 30.0 DC SINGLE LOCATION30.0 DC SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON1 PUSH BUTTON
MATERIALPLASTIC CASEPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE20.0 AMPERES AC AND 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS575.0 AC AND 575.0 AC AND 575.0 DC SINGLE LOCATION575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE1.344 INCHES NOMINAL1.344 INCHES NOMINAL
NOMINAL THREAD SIZE0.469 INCHES0.469 INCHES
POLE QUANTITY11
RESET METHODMANUALMANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT320.000 MINIMUM AT 300 PCT AND 320.000 MINIMUM AT 300 PCT AND 950.000 MAXIMUM AT 300 PCT SINGLE LOCATION950.000 MAXIMUM AT 300 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATIONTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT130.0 SINGLE LOCATION130.0 SINGLE LOCATION
STORAGE TYPEGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY2 SCREW2 SCREW
THREAD QUANTITY PER INCH3232
THREAD SERIES DESIGNATORUNSUNS